Attributes
IP67Ingress Protection
Pressuretype
Germanyplace of origin
PMC51,PMC71model number
Endress Hauserbrand name
OEM, ODMcustomized support
material:aluminum,316 SST
warranty:1 Year
Measuring principle:Absolute and gauge pressure
Communication:4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Accuracy:Up to 0.025%
Pressure measuring range:100mbar...40bar (1.5psi...600psi)
Model Number:PMC51,PMC71
Process temperature:-40°C...150°C (-40°F...302°F)
Main wetted parts:Ceraphire ceramic, Alloy C, 316L, Monel,PVDF
Overpressure limit:60bar (900psi)
Smallest calibratable span:5 mbar (0.075 psi)
Certificates / Approvals:ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex